| Version 2 (modified by thho, 16 years ago) | 
|---|
TracNav menu
- 
   System Links
- Edit Wiki Text to URL mappings
- 
   Dayabay Search
- swish dyb search
- 
   IHEP repositories
- dybsvn:/
- [dybaux:/]
- 
   NTU repositories
- env:/
- tracdev:/
- aberdeen:/
- 
   Measurements
- wiki:IAV
- wiki:OAV?
- 
   Doxygen Documentation For NuWa
- NuWaDoxygen
- 
   Mail Archives
- offline sympa archive
- simulation sympa archive
- gaudi-talk
- 
   Help
- NuWa_Trac?
- Testing_Quickstart?
- 
   BNL copies
- db:NuWa_Trac
- db:Testing_Quickstart
- 
   PDSF
- warehouse
- 
   LBL elog
- elog:/
- elog:Antineutrino_Detectors/
- elog:MDC/
- 
   Calendars
- Google Calendar
- DocDB Calendar
- 
   Dayabay Wikis
- BNL public wiki
- BNL private wiki
- IHEP twiki
- 
   Dayabay Collaboration
- Institute Map
- 
   DocDB
- DocDB
- 
   Dayabay Nightly
- dybinst-nightly
- Nightly-manual.pdf
- 
   BNL Wiki Pages
- db:Offline_Documentation
- db:SVN_Statistics
- db_:SVN
- db:Help:Contents
- db:Special:Recentchanges
- dbp:Special:Recentchanges
- dbp:SimulationGroup
- dbp:UserManual
This page contains IAV measurement raw data.
Optical Property
Sample and Data File Convention
An acrylic sample convention is composed of 4 digits.
label-batch-panel-piece
Each raw data file is composed of 6 digits. The first digit indicate the type of measurement. The following 4 digits indicate which acrylic sample is adopted. The last digit indicates the number of measurement.
type-label-batch-panel-piece-measurement
A typical convention of raw data look like:
T-B321-5
This means it's the fifth transmission measurement of the sample used for barrel of some IAV, and it's one piece of a panel ( called number 2) of batch 3.
| Label | Description | 
| B | The acrylic sample is used for the barrel of IAV | 
| L | The acrylic sample is used for the lids of IAV | 
| R | The acrylic sample is used for the ribs and flanges of IAV | 
| O | The acrylic sample is not used for the above parts of IAV | 
Nakano uses the same acrylic panels for the ribs and flanges of IAV#1 and IAV#2. If not specified, the label "R" means the acrylic sample is used for both the ribs and flanges of IAV.
| Measurement Type | Description | Details | 
| T | Total transmission | PerkinElmer Lambda 650 spectrometer | 
| R | Total reflection | PerkinElmer Lambda 650 spectrometer | 
| D | Diffuse reflection | PerkinElmer Lambda 650 spectrometer | 
| N | Index of refraction | DocDB3499 | 
| A | Absorption length | DocDB3499 | 
| O | Other kinds of measurement not mentioned above | 