| | 1 | [[TracNav(NuwaNav)]] |
| | 2 | [[PageOutline]] |
| | 3 | |
| | 4 | This page contains IAV measurement raw data. |
| | 5 | |
| | 6 | = Optical Property = |
| | 7 | == Sample and Data File Convention == |
| | 8 | An acrylic sample convention is composed of 4 digits. |
| | 9 | {{{ |
| | 10 | label-batch-panel-piece |
| | 11 | }}} |
| | 12 | |
| | 13 | Each raw data file is composed of 6 digits. |
| | 14 | The first digit indicate the type of measurement. |
| | 15 | The following 4 digits indicate which acrylic sample is adopted. |
| | 16 | The last digit indicates the number of measurement. |
| | 17 | {{{ |
| | 18 | type-label-batch-panel-piece-measurement |
| | 19 | }}} |
| | 20 | |
| | 21 | A typical convention of raw data look like: |
| | 22 | {{{ |
| | 23 | T-B321-5 |
| | 24 | }}} |
| | 25 | This means it's the fifth transmission measurement of the sample used for barrel of some IAV, and |
| | 26 | it's one piece of a panel ( called number 2) of batch 3. |
| | 27 | |
| | 28 | || Label || Description || |
| | 29 | || B || The acrylic sample is used for the barrel of IAV || |
| | 30 | || L || The acrylic sample is used for the lids of IAV || |
| | 31 | || R || The acrylic sample is used for the ribs and flanges of IAV || |
| | 32 | || O || The acrylic sample is not used for the above parts of IAV || |
| | 33 | |
| | 34 | Nakano uses the same acrylic panels for the ribs and flanges of IAV#1 and IAV#2. |
| | 35 | If not specified, the label "R" means the acrylic sample is used for both the ribs and flanges of IAV. |
| | 36 | |
| | 37 | || Measurement Type || Description || Details || |
| | 38 | || T || Total transmission || || |
| | 39 | || R || Total reflection || || |
| | 40 | || D || Diffuse reflection || || |
| | 41 | || N || Index of refraction || || |
| | 42 | || A || Absorption length || || |
| | 43 | || O || Other kinds of measurement not mentioned above || |