> > | back to ShiftCheck
<--
-->
Standard Histograms for 8 ADs
back to ShiftCheck
Known problem channels (PMT + HV channels)
When adding channels, include OHP bin numbers in addition to other channel identification. Excluding RPCs, bin numbers in OHP Channel Histograms (bin) can be related to FEE boards (slotID) and connectors (channelID+0) through the following formula: bin = (slotID - 2)*16 + channelID. The relation can be confirmed by checking PQM or ODM . Special operating conditions are noted.
- EH#1 (refilled at ???, HV on at ???) Hamamatsu:184; macro:104;
- EH#2 (Pool Re-filled at ??, HV on at ??) Hamamatsu:184; macro:104;
- EH#3 (Pool refilled at ??, HV on at ??) Hamamastu:251; Macro:133;
| No. |
Status |
detector |
DAQchID |
FEESlot-chID |
decoupler-chID |
PMTID |
Type |
Note |
| 0 |
dead |
WPI |
66 |
6-2 |
6-2 |
FCIA61 |
Macro |
updated 2012Sept28 |
| 1 |
dead |
WPO |
83 |
7-3 |
6-45 |
FVIA43 |
Macro |
updated 2012Sept28 |
| 2 |
dead |
WPO |
87 |
7-7 |
5-45 |
FVOA43 |
Macro |
updated 2012Sept28 |
| 3 |
dead |
WPO |
135 |
10-7 |
1-09 |
FVOC43 |
Macro |
updated 2012Sept28 |
| 4 |
dead |
WPO |
163 |
12-3 |
2-17 |
FVIE41 |
Macro |
updated 2012Sept28 |
| 5 |
dead |
WPO |
174 |
12-14 |
3-18 |
FVOE32 |
Macro |
not replaced, updated 2012Sept28 |
| 6 |
dead |
WPO |
214 |
15-6 |
1-30 |
FVOG31 |
Macro |
updated 2012Sept28 |
| 7 |
fewSignal |
WPO |
231 |
16-7 |
1-33 |
FVOG43 |
Macro |
HV=1384.6V, 11.5Mohm, few pulse, nearly no >15mV pulse,updated 2012Sept28 |
| 8 |
noisy |
WPO |
159 |
11-15 |
3-13 |
FVOD42 |
Macro |
many small pulses, still working,updated 2012Sept28 |
| 9 |
large pusle |
WPI |
169 |
12-9 |
8-27 |
FCIG63 |
Macro |
many large pulse, still working ,updated 2012Sept28 |
| 10 |
dead |
AD6 |
110 |
8-14 |
?-? |
L2C3R7 |
Hama |
http://web.dyb.ihep.ac.cn:8099/Commissioning/876 |
Reference Elog: http://web.dyb.ihep.ac.cn:8099/Water+Cerenkov+Detectors/486
back to ShiftCheck
|

Copyright © by the contributing authors, 2007-2026.
Ideas, requests, problems regarding Daya Bay?
Send feedback